Filter Results By:

Products

Applications

Manufacturers

Showing results: 1516 - 1530 of 2617 items found.

  • Tungsten Probe Tips

    T-4 Series - Picoprobe

    T-4 tips are for use in most standard commercial micropositioners for probing integrated circuits, pads, or lines. Each T-4 tip uses the same 10, 22, 35, 60, or 125 micron diameter tungsten wire as our Model 12C Picoprobe, but is mounted to a 0.020 inch diameter, 2 inch long tinned copper shaft.

  • Linear Regulated Power Supplies (to 150 watts)

    Gold Box "Infinity" - Acopian Technical Company

    *Highly Configurable, with a seemingly Infinite number of Options*Any slot voltage from 1.5v to 150v is available*Remote Sensing*Open Sense protection*Isolated output*Short circuit and overload protection with enhanced surge capabilities*No minimum load required*Internal EMI Filtering*Pluggable connectors*Can be mounted on two surfaces in any orientation

  • Voltage Breakdown Testing Machine

    DRK218 - Shandong Drick Instruments Co., Ltd.

    DRK218 breakdown voltage tester is controlled by the computer, through a new smart digital integrated circuits developed by my company and software control system to make the step-up rate is truly uniform, accurate, and be able to accurately measure the leakage current data. Real-time rendering test curve accurate judgment and it can save, analyze and print test data.

  • Clamshell Fixtures (Top Side Probing)

    Arcadia Test

    Clamshell fixtures are used to test circuit boards from both the top and bottom sides simultaneously. Arcadia offers various assemblies to accommodate this. Whether you require vacuum, pneumatics, or mechanically actuated Z motion lids, we have numerous sizes available from off our shelf inventory to meet every need.

  • AC & DC Analog Leakage Meters

    2108 EL - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Four functions : DC current, AC current, AC+DC current, and ACV measurement.● Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.● 200uA full scale value.● ±2.5% full scale value accuracy.● Built-in overload protection circuit.● Robust, compact and easy to carry.

  • 9U 21 Slot VME64X Enhanced Crate

    VME8200 - CAEN S.p.A.

    The power supply is placed in the bottom, behind the fan tray unit, in order to keep the rear of the VME backplane completely accessible. Safety features include: short circuit protection, Over / Under voltage protection, Over temperature protection. Remote monitoring and control take place through CAN bus, Ethernet, USB and RS232 interfaces.

  • Test Analyzer

    ST2303 - Shenzhen Star Instrument Co., Ltd.

    The ST2303 three-phase energy meter field test analyzer reaches accuracy class 0.05. It generates stable signals by using ARM and digital signal processing technologies. Its highlights include compactness, light weight and portability. Various supply options, including measuring circuit, external AC power supply and internal lithium battery are offered.

  • Rugged VPX Power Supplies

    North Atlantic Industries

    The NAI VPX family of power products include a variety of standard features, including continuous Background Built-In-Test (BIT); remote error sensing; and protection against transients, overvoltage, overcurrent, short circuits and over temperature. These intelligent designs also have the flexibility to address special needs. Optional current share is available on main outputs.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • Series Flame Detector

    DF-TV7 - Teledyne Gas & Flame Detection

    The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can ​​be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.​​​​​​​​​​​​​​​​​​​​

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Integrated Ultrasonic Level Gauge

    HR9100T - HighReach Measuring & Controlling System Co.,Ltd

    1. The circuit design selects high-quality power module components from the power supply part to select high-stability and reliable devices, which can completely replace the same type of imported instruments. 2. The patented sonic intelligent technology software can perform intelligent echo analysis the debugging and the any OTHER Special the without Steps. This Technology has Dynamic Thinking at The Functions of the Analysis and Dynamic. 3. Sound Wave at The Patented Technology of Our Company Makes at The Accuracy of at The Instrument Greatly Improved, at The Precision Liquid Level Reaches 0.25%, and IT CAN Resist various kinds of interference waves.4. This instrument is a kind of non-contact instrument, which does not directly contact with liquid., the instrument has a variety of installation methods. The user can use this manual to calibrate the instrument. 5. All input and output lines Of the instrument have lightning protection and short circuit protection.

  • Compact Uncooled LWIR Cores

    MicroCalibir - Teledyne DALSA

    The latest advances in the integration of our in-house 12 μm microbolometer pixel technology with a deep-ADC ROIC circuit have resulted in the development of the small and lightweight MicroCalibir™. This compact, low-power uncooled thermal camera platform features the smallest VGA IR core module on the market making it ideal for OEM drones, handhelds, helmet-mounted and vehicular integration products.

  • Electric Shock Protection Analysis

    ETAP Enterprise

    60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel

  • Function Generators

    Scientific Mes-Technik Private Ltd

    Scientific offer wide range of function generators from 3 MHz to 10 MHz in general purpose and multifunction. Selection of waveform shapes apart from standard sine, triangle , square to ramp, pulse are available. SM5071 , SM5074 , SM5061 & SM5075 have built-in auto ranging frequency counter. The outputs are protected against short circuits and overload.

Get Help